Energy Recovery Products

*

Search SEMCO

 

*
Pinnacle - Primary Ventilation System

The Pinnacle® system offers a cost effective solution to the ventilation mandate and the humidity control dilemma facing designers as a result of ASHRAE Standard 62. The system’s flexibility allows engineers to consider whole new design schemes. This is a result of its ability to provide very dry outdoor air in a straight forward, simple, energy efficient manner delivered by a totally integrated packaged system.

A very significant reduction in energy consumption during the cooling season is recognized with the Pinnacle system when compared to conventional over-cool and reheat designs applied most often today. These reductions are typically in the range of 50 to 60%. With the Pinnacle system, wintertime heating and humidification is reduced to only 10 to 15% of what it would be without the system. As importantly, the unoccupied dehumidification, made possible with the technology, allows building owners to maintain humidity levels during unoccupied times at a fraction of the cost of alternate systems.

As a result, the application of this novel Pinnacle preconditioning technology has the potential for reducing future energy consumption of commercial buildings in the U.S. Moreover, it will also offset a significant energy increase that would otherwise come as a result of the increased compliance with IAQ code requirements (i.e. ASHRAE Standard 62).

Product Library

Select a category 

1100 Peachtree Building (38 kB) pdf
Description: After 10 years, energy recovery still delivers for Atlanta building.

Georgia Institute of Technology (127 kB) pdf
Description: A desiccant-based system in place at a Georgia Institute of Technology dormitory is maximizing indoor air quality while minimizing energy consumption.

High-Performance Schools  (2248 kB) pdf
Description: High Marks for Energy Efficiency, Humidity Control, Indoor Air Quality & First Cost

Johns Hopkins School of Medicine (218 kB) pdf
Description: A desiccant system has improved air quality; halved cooling requirements, and reduced heating and humidification requirements by more than two-thirds at the Johns Hopkins School of Medicine.

Northville High School (36 kB) pdf
Description: Wheels turning for energy savings at high school.

Red Wing High School (117 kB) pdf
Description: Equipment earns high grades.

Redi-Floors Inc (57 kB) pdf
Description: An office-warehouse owner virtually eliminated tobacco smoke and controlled other contaminants by retrofitting his building's ventilation system. Here's what he did - and why.

Report Card on Humidity Control (2271 kB) pdf
Description: Failing Grade for Many Schools.

SEMCO Pioneers Indoor Environmentalism (116 kB) pdf

  *
*
*
*
Feedback Questions and Comments?
© 2007 SEMCO Incorporated, a Fläkt Woods Company | Legal