- Novel System Design
- Efficient and economical design meeting the needs of the conventional HVAC market.
- Compact, low profile design to conform to typical architectural requirements.
- Easy access to all internal components through a large hinged access door and removable roof panel.
- Outdoor air inlet and exhaust air outlet located at opposite ends of unit for maximum separation.
- The TEC Total Energy Wheel
- Certified total energy (both sensible and latent) recovery performance.
- Easily removable wheel cassette module.
- Surpasses NFPA-90A requirements having a smoke and flame spread rating of 0 and 0, vs. 50 and 25 allowed by the standard.
- Self-adjusting air seals.
- Cabinet Construction
- Galvanized steel cabinet construction with enamel finish.
- Entire cabinet insulated to minimize energy loss.
- Hinged doors for easy access.
- Floor of the unit built as a pan to ensure watertight design.
- Supply and Exhaust Air Fans
- Sized for quiet and efficient operation.
- Mounted and balanced.
- Multiple speed motors or multiple motor/sheave selections for efficient adjustment of airflow.
- Filter Sections
- Filtration provided for both the outdoor air and return air.
- Hoods and Dampers
- Airflow balancing dampers.
- Unit provided with an intake hood with cleanable filter to limit rain and snow introduction.
- Exhaust air back draft damper on outside units only.
- Electrical Package with Single Point Connection
- All motors wired to starters.
- Accepts contact inputs for supply fan start/stop, wheel start/stop and unit start/stop.
- Multiple options on input voltage to units:
FV-600TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-1000TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-2000TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-3000TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-4000TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-5000TS |
|
208, 240V 1Ø
208, 240, 480V 3Ø |
FV-7500TS |
|
208, 240, 480V 3Ø |
FV-9000TS |
|
208, 240, 480V 3Ø |
- AQFlow® Airflow Measuring System
- Simpler, more accurate system balancing in just five minutes.
- Easy measuring and adjusting of outdoor and exhaust air quantities.
- Accurate airflow measurement (+/-6%) for the FV-TS unit or when mounted to a package rooftop unit where measuring outdoor air quantities is difficult.
- Reduced calls to engineers regarding air quantities.
- Peace of mind that proper ventilation is being provided to building occupants.
- Quick detection of problems like dirty filters, motor failure, power outage, etc.
- Meets intent of current and future ASHRAE standards for monitoring delivered fresh air quantities.
- Electric Preheat (Optional)
- An electric preheat coil can be provided to avoid frosting conditions for installations in cold climates that have high indoor humidity design conditions.
- Thermostat Frost Protection (Optional)
- Thermostatic frost control allows the entire FV-TS unit to be turned off at a predetermined temperature when electric preheat is not desired.
- Control Options (Optional)
- Stop/Jog Economizer board allows the wheel to be stopped automatically during mild outdoor temperatures with periodic brief rotation to maintain the self-cleaning feature of the heat exchanger.
- Wheel Frost Protection allows the wheel only to be stopped by the stop/jog economizer board at a predetermined outdoor temperature in applications where a preheat coil or thermostat shut-off of the FV-TS unit is not desired.
- Rotation Detector Sensor can provide an alarm signal indicating failure of the wheel rotation.
|
 |
|
 |
 |
Product Library | Select a category
|
 |
Coral Reef Yacht Club (66 kB)  Description: Ventilation unit recovers energy while resolving smoking issues.
Report Card on Humidity Control (2271 kB)  Description: Failing Grade for Many Schools.
SEMCO Pioneers Indoor Environmentalism (116 kB) 
Wizard's Sports Cafe (55 kB)  Description: Sports Bar/Restaurant Clears the Air.
|
 |
|
Trane, Voyager, Precedent, and Modular Climate Changer are registered trademarks of American Standard Incorporated.
|