Energy Recovery Products

*

Search SEMCO

 

*

FV Series - Fresh Air Ventilator

The SEMCO FV (Fresh Air Ventilator) Series of outdoor air pre-conditioners have been specifically designed to reduce the energy required to heat or cool outdoor air by up to 80 percent. The FV pre-conditioner allows the HVAC system to effectively and economically accommodate the three-to-four-fold increase in outdoor air quantities, which is recommended by the ASHRAE Standard 62, Ventilation for Acceptable Indoor Air Quality. This unique capability allows both new and existing buildings to benefit from a healthy indoor environment.

SEMCO's FV pre-conditioner significantly reduces the operating cost of a facility designed in accordance with the ASHRAE IAQ standard. It also improves humidity control when combined with unitary heating and cooling equipment. Because the SEMCO unit preconditions the incoming air to the packaged equipment, the required refrigeration capacity may be reduced by as much as 50 percent. Thus, the cost of the FV pre-conditioner and its installation is typically offset by the reduced size of the conventional HVAC system.

In existing facilities, retrofitting the HVAC system with an FV pre-conditioner allows the outdoor air quantity to be increased significantly without raising energy costs, losing humidity control, or changing the size of the current HVAC unit.

Product Library

Select a category 

1100 Peachtree Building (38 kB) pdf
Description: After 10 years, energy recovery still delivers for Atlanta building.

Coral Reef Yacht Club (66 kB) pdf
Description: Ventilation unit recovers energy while resolving smoking issues.

High-Performance Schools  (2248 kB) pdf
Description: High Marks for Energy Efficiency, Humidity Control, Indoor Air Quality & First Cost

Northville High School (36 kB) pdf
Description: Wheels turning for energy savings at high school.

Red Wing High School (117 kB) pdf
Description: Equipment earns high grades.

Redi-Floors Inc (57 kB) pdf
Description: An office-warehouse owner virtually eliminated tobacco smoke and controlled other contaminants by retrofitting his building's ventilation system. Here's what he did - and why.

Report Card on Humidity Control (2271 kB) pdf
Description: Failing Grade for Many Schools.

SEMCO Pioneers Indoor Environmentalism (116 kB) pdf

Wizard's Sports Cafe (55 kB) pdf
Description: Sports Bar/Restaurant Clears the Air.

  *
*
*
*
Feedback Questions and Comments?