Energy Recovery Products

*

Search SEMCO

 

*

EP Series - Total Energy Recovery

SEMCO's EP Series offers the ultimate performance in the transfer of total energy (both latent and sensible). Pre-engineered and factory assembled, the EP Series system also provides the air handling capability for the building's exhaust and supply air. The system can be selected to precondition outdoor air going to other conventional air handling systems or as an integrated system that provides total space conditioning with additional heating and cooling options available.

The heart of this system is a technologically advanced EXCLU-SIEVE® desiccant wheel. In addition to providing superior performance, the wheel's 3Å molecular sieve-desiccant coating is selective in what it adsorbs from an exhaust air stream. The desiccant rejects airborne contaminants while it transfers water vapor, thus providing total energy transfer from the exhaust to the supply air stream. Selectivity allows EXCLU-SIEVE to be used in critical applications, including recovery from contaminated air streams. In the past, energy recovery was avoided or limited to sensible-only energy exchange in applications like these.

The EXCLU-SIEVE wheel uses a fluted media with an aluminum backbone, which is coated with a fast-acting, adsorbent desiccant surface. As the transfer media slowly rotates between the outdoor and exhaust air streams, the warmer air surrenders its sensible energy to the aluminum. This energy is then shifted to the cooler air stream during the second half of the revolution.

Just as the temperature is captured and released, so is the moisture. EXCLU-SIEVE's 3Å molecular sieve-desiccant coating has an enormous internal surface area and strong attraction to water vapor. Since the opposing air streams have different temperatures and moisture contents, the vapor pressure will also be different. This pressure difference is the driving force in the transferring of latent energy.

By using the desiccant coating, EXCLU-SIEVE recovers the moisture from the exhaust air stream to the supply air stream without the airborne pollutants exchanging. This very important and unique feature has been well documented through independent laboratory and field-testing.

Configurations

This product builds on the EP product but integrates full cooling for humidity control and a sensible energy wheel to provide free reheat. This dual-wall system contains an EXCLU-SIEVE® energy recovery wheel, a sensible energy wheel, backward curved, supply and exhaust fans, outdoor air and return air filtration, cooling coil, limited capacity reheat coil and an optional full-electrical package including a single-point electrical connection. The cooling options include either chilled water or DX cooling coils, with options regarding the number of fins per inch and the number of row options. The heating options include either hot water, steam or electric coils.

The applications for this product include buildings that need high percentages of outdoor air for a humidity controlled environment where the SEMCO system provides 45-55 grains of water/pound of dry air and a neutral temperature of 65-70 degrees to the space. This approach allows conventional HVAC systems to operate most efficiently by cycling on and off, while using all re-circulated air and handling only sensible loads. Good applications for the EPD systems include classrooms, hotels, dormitories, casinos and laboratories. This approach to ventilation of humidity control is very energy efficient since the EPD system can generate up to 10 tons of latent cooling for every 3 tons input with no cost of re-heating.


Product Library

Select a category 

1100 Peachtree Building (38 kB) pdf
Description: After 10 years, energy recovery still delivers for Atlanta building.

Georgia Institute of Technology (127 kB) pdf
Description: A desiccant-based system in place at a Georgia Institute of Technology dormitory is maximizing indoor air quality while minimizing energy consumption.

High-Performance Schools  (2248 kB) pdf
Description: High Marks for Energy Efficiency, Humidity Control, Indoor Air Quality & First Cost

Johns Hopkins School of Medicine (218 kB) pdf
Description: A desiccant system has improved air quality; halved cooling requirements, and reduced heating and humidification requirements by more than two-thirds at the Johns Hopkins School of Medicine.

Northville High School (36 kB) pdf
Description: Wheels turning for energy savings at high school.

Red Wing High School (117 kB) pdf
Description: Equipment earns high grades.

Redi-Floors Inc (57 kB) pdf
Description: An office-warehouse owner virtually eliminated tobacco smoke and controlled other contaminants by retrofitting his building's ventilation system. Here's what he did - and why.

Report Card on Humidity Control (2271 kB) pdf
Description: Failing Grade for Many Schools.

SEMCO Pioneers Indoor Environmentalism (116 kB) pdf

  *
*
*
*
Feedback Questions and Comments?